CR8 Pacemaker Certification
CR8 Pacemaker Certification
To supply information related to Pacemaker registry
Position
Element
Name
Type
Requirement
Min
Max
Repeat
CR8-01
Implant Type Code
Identifier (ID)
Mandatory
1
1
-
Code identifying implant components
CR8-02
Implant Status Code
Identifier (ID)
Mandatory
1
1
-
Code identifying the status of implant components
CR8-03
Date
Date (DT)
Mandatory
8
8
-
Date expressed as CCYYMMDD
CR803 is the warranty expiration date.
CR8-04
Date
Date (DT)
Mandatory
8
8
-
Date expressed as CCYYMMDD
CR804 is the implant date.
CR8-05
Reference Identification
String (AN)
Mandatory
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
CR805 is the manufacturer identification.
CR8-06
Reference Identification
String (AN)
Mandatory
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
CR806 is the model number.
CR8-07
Reference Identification
String (AN)
Mandatory
1
30
-
Reference information as defined for a particular Transaction Set or as specified by the Reference Identification Qualifier
CR807 is the serial number.
CR8-08
Yes/No Condition or Response Code
Identifier (ID)
Mandatory
1
1
-
Code indicating a Yes or No condition or response
CR808 indicates if leads were left in the patient. A "Y" value indicates leads were left in patient; an "N" value indicates leads were not left in patient.
CR8-09
Yes/No Condition or Response Code
Identifier (ID)
Mandatory
1
1
-
Code indicating a Yes or No condition or response
CR809 indicates if the pacemaker was returned to the manufacturer. A "Y" value indicates the pacemaker was returned to the manufacturer; an "N" value indicates the pacemaker was not returned to the manufacturer.