W09 Equipment and Temperature
W09 Equipment and Temperature
To relate equipment type and required temperatures
Position
Element
Name
Type
Requirement
Min
Max
Repeat
W09-01
Equipment Description Code
Identifier (ID)
Mandatory
2
2
-
Code identifying type of equipment used for shipment
W09-02
Temperature
Decimal number (R)
Conditional
1
4
-
Temperature
W0902 is the minimum allowable temperature condition for shipment; (the qualifying temperature scale is specified in W0903).
W09-03
Unit or Basis for Measurement Code
Identifier (ID)
Conditional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
W09-04
Temperature
Decimal number (R)
Conditional
1
4
-
Temperature
W0904 is the maximum allowable temperature condition for shipment; (the qualifying temperature scale is specified in W0905).
W09-05
Unit or Basis for Measurement Code
Identifier (ID)
Conditional
2
2
-
Code specifying the units in which a value is being expressed, or manner in which a measurement has been taken
W09-06
Free Form Message
String (AN)
Optional
1
60
-
Free-form text
W0906 is used to describe the environment required within an ocean-type, refrigerated container when other than normal air is required.
W09-07
Vent Setting Code
Identifier (ID)
Optional
1
1
-
Code describing the setting on the air vents on ocean-type containers
W09-08
Percent
Numeric (N0)
Optional
1
3
-
Percent expressed as 0 to 100
W0908 is the humidity percentage.
W09-09
Quantity
Decimal number (R)
Optional
1
15
-
Numeric value of quantity
W0909 is the number of air exchanges per hour.